Gamma Ray Sterilization Study on a Perna perna Mussel Reference Material

Authors

  • Edson Gonçalves Moreira Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP Centro do Reator de Pesquisas, CRPq
  • Mônica Beatriz Mathor Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP Centro de Tecnologia das Radiações, CTR
  • Marina Beatriz Agostini Vasconcellos Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP Centro do Reator de Pesquisas, CRPq

Abstract

In this study the most suitable gamma ray dose for the sterilization of a new Perna perna mussel reference material was investigated. Different gamma ray doses were applied and microbiological loads of irradiated subsamples and a non-irradiated control subsample were studied. A 0.90 kGy decimal reduction value was estimated at the microbiological load test conditions and it was concluded that a 5 kGy dose is suitable for the sterilization of the mussel reference material.

Downloads

Published

19-06-2013

How to Cite

Moreira, E. G., Mathor, M. B., & Vasconcellos, M. B. A. (2013). Gamma Ray Sterilization Study on a Perna perna Mussel Reference Material. Ecotoxicology and Environmental Contamination, 8(1), 149–152. Retrieved from https://periodicos.univali.br/index.php/eec/article/view/3476

Issue

Section

Short Communication